NFPA 286: Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
Current Edition: 2015 Next Edition: 2019

Alerts: Receive e-mail updates on this document Manage my alerts

Alert Me
Please confirm you would like to be alerted the next time we post new information about document .
Alerts will be sent to the e-mail address on your user profile:

Thank you for signing up for alerts.

Committee members: Sign-in to view your documents.
What is NFPA 286?
NFPA 286: Document Scope

1.1* Scope. This standard describes a method for determining the contribution of interior finish materials to room fire growth during specified fire exposure conditions. A.1.1 The performance of all wall and ceiling covering systems is addressed in this standard. Textile and expanded vinyl wall covering systems are included in this standard and they are also addressed specifically in NFPA 265, Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile or Expanded Vinyl Wall Coverings on Full Height Panels and Walls. Further information on testing of textile wall coverings can be found in Fisher et al., Room Fire Tests of TextileWall Coverings. Textile and expanded vinyl wall coverings are permitted by some codes (e.g., NFPA 101, Life Safety Code ) to be tested using NFPA 265. 1.1.1 This method is intended for the evaluation of the flammability characteristics of wall and ceiling interior finish, where such materials constitute the exposed interior surfaces of buildings. 1.1.2 This fire test method is not intended for the evaluation of fire resistance of assemblies, nor is it intended for the evaluation of the effect of fires that originate within a wall assembly. 1.1.3 This standard specifies three types of specimen mounting, depending on the application of the interior finish material, as follows: (1) Three walls (for interior finish to be used on walls only) (2) Three walls and the ceiling (for interior finish to be used on walls and ceilings) (3) The ceiling alone (for interior finish to be used on ceilings only)

This standard describes a method for determining the contribution of interior finish materials to room fire growth during specified fire exposure conditions. It is intended for the evaluation of the flammability characteristics of wall and ceiling interior finish, other than textile wall coverings, where such materials constitute the exposed interior surfaces of buildings. This test is also known as the “room corner” test. Official document scope
What does NFPA 286 address?
Measurements in the fire test room document extent of fire growth, rate of heat release, total heat released, time to flashover, time to flame extension, total heat flux incident to the floor, upper level gas temperature, smoke obscuration, production of carbon monoxide, and emissions of other combustion gases.