NFPA® 750 Standard on Water Mist Fire Protection Systems 2010 Edition

Chapter 1 Administration
1.1 Scope
1.2 Purpose
1.3 Application
1.4 Retroactivity
1.5 Equivalency
1.6 Units
Chapter 2 Referenced Publications
2.1 General
2.2 NFPA Publications
2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
Chapter 3 Definitions
3.1 General
3.2 NFPA Official Definitions
3.3 General Definitions
Chapter 4 General
4.1 General
4.2 Safety.
Chapter 5 System Components and Hardware
5.1 General.
5.2 Gas and Water Containers
5.3 Piping and Tube
5.4 Fittings
5.5 Hangers/Supports
5.6 Nozzles
5.7 Valves
5.8 Strainers and Filters
5.9 Pump Systems
5.10 Detection, Actuation, Alarm, and Control Systems
5.11 Compatibility
Chapter 6 System Requirements
6.1 General
6.2 System Applications
6.3 Nozzle Types
6.4 System Requirements.
6.5 Media System Types
6.6 Additive Systems
Chapter 7 Installation Requirements
7.1 General.
7.2 Nozzles
7.3 Pipe and Tubing
7.4 Fittings
7.5 Gas and Water Storage Containers
7.6 Pumps and Pump Controllers
7.7 Strainers and Filters
7.8 Valves and Pressure Gauges
7.9 Electrical Systems
7.10 Test Connections
Chapter 8 Design Objectives and Fire Test Protocols
8.1 General
8.2 Listing Evaluations
8.3 Performance Objectives
8.4 Application Parameters
8.5 Reliability
Chapter 9 Calculations
9.1 General
9.2 Darcy–Weisbach Calculation Method for Intermediate and High Pressure, Single Fluid, Single Liquid Phase Systems
9.3 Hazen–Williams Calculation Method (Low Pressure Systems)
9.4 Calculation Procedures for Propellant Gas or Atomizing Media
Chapter 10 Water Supplies and Atomizing Media
10.1 General
10.2 Quantity
10.3 Duration
10.4 Reserve Supplies
10.5 Water Supplies
10.6 Atomizing Media for Twin-Fluid Systems
10.7 Pressure Gauges
Chapter 11 Plans and Documentation
11.1 Working Plans
11.2 Hydraulic Calculation Documentation
11.3 Pneumatic Calculation Documentation
11.4 Detection, Actuation, and Control Systems Documentation
Chapter 12 System Acceptance
12.1 Approval of Water Mist Systems
12.2 Acceptance Requirements
Chapter 13 System Maintenance
13.1 Responsibility of the Owner or Occupant
13.2 Inspection and Testing
13.3 Maintenance
13.4 Training
Chapter 14 Marine Systems
14.1 General
14.2 Sprinkler Equivalent Systems
14.3 Flammable Liquids — Total Area Protection
14.4 Human Factors
14.5 Requirements for Water Mist Systems on Combatant Vessels
Annex A Explanatory Material
Annex B Research Summary
Annex C Examples of Fire Test Protocols
Annex D Reliability
Annex E Informational References
Index
Important Notices and Disclaimers
Additional Notices and Disclaimers