NFPA 20: Stationary Fire Pumps Handbook, 2013 Edition
| Description | Table of Contents | Sample Pages | Quantity Discounts |
Contents
Preface
Acknowledgments
Dedication
About the Contributors
About the Editor
PART ONE
An Overview of Fire Pump Configurations
PART TWO
NFPA 20, Standard for the Installation of
Stationary Pumps for Fire Protection, 2013 Edition, with Commentary
1 Administration
1.1 Scope
1.2 Purpose
1.3 Application
1.4 Retroactivity
1.5 Equivalency
1.6 Units
2 Referenced
Publications
2.1 General
2.2 NFPA Publications
2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
3 Definitions
3.1 General
3.2 NFPA Official Definitions
3.3 General Definitions
4 General Requirements
4.1 Pumps
4.2 Approval Required
4.3 Pump Operation
4.4 Fire Pump Unit Performance
4.5 Certified Shop Test
4.6 Liquid Supplies
4.7 Pumps, Drivers, and Controllers
4.8 Centrifugal Fire Pump Capacities
4.9 Nameplate
4.10 Pressure Gauges
4.11 Circulation Relief Valve
4.12 Equipment Protection
4.13 Pipe and Fittings
4.14 Suction Pipe and Fittings
4.15 Discharge Pipe and Fittings
4.16 Valve Supervision
4.17 Protection of Piping Against Damage Due to Movement
4.18 Relief Valves for Centrifugal Pumps
4.19 Pumps Arranged in Series
4.20 Water Flow Test Devices
4.21 Steam Power Supply Dependability
4.22 Shop Tests
4.23 Pump Shaft Rotation
4.24 Other Signals
4.25 Pressure Maintenance (Jockey or Make-Up) Pumps
4.26 Summary of Centrifugal Fire Pump Data
4.27 Backflow Preventers and Check Valves
4.28 Earthquake Protection
4.29 Packaged Fire Pump Assemblies
4.30 Pressure Actuated Controller Pressure Sensing Lines
4.31 Break Tanks
4.32
Field Acceptance Test of Pump Units
5 Fire Pumps for
High-Rise Buildings
5.1 General
5.2 Equipment Access
5.3 Water Supply Tanks
5.4 Fire Pump Test Arrangement
5.5 Auxiliary Power
5.6 Very Tall Buildings
6 Centrifugal Pumps
6.1 General
6.2 Factory and Field Performance
6.3 Fittings
6.4 Foundation and Setting
6.5 Connection to Driver and Alignment
7 Vertical Shaft
Turbine–Type Pumps
7.1 General
7.2 Water Supply
7.3 Pump
7.4 Installation
7.5 Driver
7.6 Operation and Maintenance
8 Positive
Displacement Pumps
8.1 General
8.2 Foam Concentrate and Additive Pumps
8.3 Water Mist System Pumps
8.4 Water Mist Positive Displacement Pumping Units
8.5 Fittings
8.6 Pump Drivers
8.7 Controllers
8.8 Foundation and Setting
8.9 Driver Connection and Alignment
8.10 Flow Test Devices
9 Electric Drive for
Pumps
9.1 General
9.2 Normal Power
9.3 Alternate Power
9.4 Voltage Drop
9.5 Motors
9.6 On-Site Standby Generator Systems
9.7 Junction Boxes
9.8 Listed Electrical Circuit Protective System to Controller
Wiring
9.9 Raceway Terminations
10 Electric-Drive
Controllers and Accessories
10.1 General
10.2 Location
10.3 Construction
10.4 Components
10.5 Starting and Control
10.6 Controllers Rated in Excess of 600 V
10.7 Limited Service Controllers
10.8 Power Transfer for Alternate Power Supply
10.9 Controllers for Additive Pump Motors
10.10 Controllers with Variable Speed Pressure Limiting Control or
Variable Speed Suction Limiting Control
11 Diesel Engine Drive
11.1 General
11.2 Engines
11.3 Pump Room
11.4 Fuel Supply and Arrangement
11.5 Engine Exhaust
11.6 Diesel Engine Driver System Operation
12 Engine Drive
Controllers
12.1 Application
12.2 Location
12.3 Construction
12.4 Components
12.5 Battery Recharging
12.6 Battery Chargers
12.7 Starting and Control
12.8 Air-Starting Engine Controllers
13 Steam Turbine Drive
13.1 General
13.2 Turbine
13.3
Installation
14 Acceptance Testing,
Performance, and Maintenance
14.1 Hydrostatic Tests and Flushing
14.2 Field Acceptance Tests
14.3 Record Drawings, Test Reports, Manuals, Special Tools, and
Spare Parts
14.4 Periodic Inspection, Testing, and Maintenance
14.5 Component Replacement
Annexes
Annex A Explanatory Material
Annex B Possible Causes of Pump Troubles
Annex C Informational References
Annex D Material Extracted by NFPA 70, Article 695
PART THREE
Water Supply Requirements, Water Demand, Hydrants, Tanks, and Piping
Section 1 Complete Text of NFPA 291, Recommended Practice for Fire
Flow Testing and Marking of Hydrants, 2013 Edition, with Commentary
Section 2 Complete Text of NFPA 24, Standard for the Installation
of Private Fire Service Mains and Their Appurtenances, 2013 Edition, with
Commentary
Section 3 Section 18.4 and Annex E, NFPA 1, Fire Code, 2012
Edition, with Commentary
Section 4 Extracts with Commentary from NFPA 22, Standard for
Water Tanks for Private Fire Protection, 2008 Edition
Section 5 Extracts with Commentary from NFPA 14, Standard for the
Installation of Standpipe and Hose Systems, 2010 Edition
Section 6 Extracts with Commentary from NFPA 13, Standard for the
Installation of Sprinkler Systems, 2013 Edition
PART FOUR
Supplements
1 Interrelationship of NFPA Standards Pertaining to a Fire Pump
Installation
2 Commissioning and Inspection, Testing, and Maintenance Forms for
Fire Pumps
3 NEC® Article 695, Fire Pumps
4 Technical/Substantive Changes from the 2010 to the 2013 Edition
of NFPA 20
NFPA 20 Index
Important Notices and Legal Disclaimers
| CUSTOMERS ALSO BOUGHT |
| YOU MIGHT ALSO LIKE |
|
|







