NFPA 25: Water-Based Fire Protection Systems Handbook, 2011 Edition
| Description | Table of Contents | Sample Pages | Quantity Discounts | Testimonials |
Contents
Preface
About the Contributors
About the Editors
PART ONE
NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2011 edition, with Commentary
1 Administration
1.1 Scope
1.2 Purpose
1.3 Application
1.4 Units
2 Referenced Publications
2.1 General
2.2 NFPA Publications
2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
3 Definitions
3.1 General
3.2 NFPA Official Definitions
3.3 General Definitions
3.4 Deluge Foam-Water Sprinkler and Foam-Water Spray Systems
Definitions
3.5 Valve Definitions
3.6 Water-Based Fire Protection System Definitions
4 General Requirements
4.1 Responsibility of the Property Owner or Designated
Representative
4.2 Corrective Action
4.3 Records
4.4 Inspection
4.5 Testing
4.6 Performance-Based Programs
4.7 Maintenance
4.8 Safety
5 Sprinkler Systems
5.1 General
5.2 Inspection
5.3 Testing
5.4 Maintenance
5.5 Component Action Requirements
6 Standpipe and Hose Systems
6.1 General
6.2 Inspection
6.3 Testing
6.4 Maintenance
6.5 Component Action Requirements
7 Private Fire Service Mains
7.1 General
7.2 Inspection and Corrective Action
7.3 Testing
7.4 Maintenance
7.5 Component Action Requirements
8 Fire Pumps
8.1 General
8.2 Inspection
8.3 Testing
8.4 Reports
8.5 Maintenance
8.6 Component Replacement Testing Requirements
9 Water Storage Tanks
9.1 General
9.2 Inspection
9.3 Testing
9.4 Maintenance
9.5 Automatic Tank Fill Valves
9.6
Component Action Requirements
10 Water Spray Fixed Systems
10.1 General
10.2 Inspection and Maintenance Procedures
10.3 Operational Tests
10.4 Ultra-High-Speed Water Spray System (UHSWSS) Operational
Tests
10.5 Component Action Requirements
11 Foam-Water Sprinkler Systems
11.1 General
11.2 Inspection
11.3 Operational Tests
11.4 Maintenance
11.5 Component Action Requirements
12 Water Mist Systems
12.1 Inspection and Testing
12.2 Maintenance
12.3 Training
13 Valves, Valve Components, and Trim
13.1 General
13.2 General Provisions
13.3 Control Valves in Water-Based Fire Protection Systems
13.4 System Valves
13.5 Pressure Reducing Valves and Relief Valves
13.6 Backflow Prevention Assemblies
13.7 Fire Department Connections
13.8 Component Testing Requirements
14 Obstruction Investigation
14.1 General
14.2 Internal Inspection of Piping
14.3 Obstruction Investigation and Prevention
14.4 Ice Obstruction
15 Impairments
15.1 General
15.2 Impairment Coordinator
15.3
Tag Impairment System
15.4 Impaired Equipment
15.5 Preplanned Impairment Programs
15.6 Emergency Impairments
15.7 Restoring Systems to Service
Annexes
A Explanatory Material
B Forms for Inspection, Testing, and Maintenance
C Possible Causes of Pump Troubles
D Obstruction Investigation
E Examples of Classifications of Needed Repairs
F Hazard Evaluation Form
G Informational References
PART TWO
Supplements
1 Microbiologically Influenced Corrosion in Fire Sprinkler Systems
2 Foam Environmental Issues
3 Role of the Inspector
4 Role of the Owner or Designated Representative
5 Technical/Substantive Changes from the 2008 Edition to the 2011
Edition of NFPA 25
Index
Important Notices and Legal Disclaimers
| CUSTOMERS ALSO BOUGHT |
| YOU MIGHT ALSO LIKE |
|
|







