NFPA 214: Standard on Water-Cooling Towers
Current Edition: 2011 Next Edition: 2016

Alerts: Receive e-mail updates on this document Manage my alerts

Alert Me
Please confirm you would like to be alerted the next time we post new information about document .
Alerts will be sent to the e-mail address on your user profile:

Thank you for signing up for alerts.

Committee members: Sign-in to view your documents.
Buy This Edition
NFPA 214:
2011 Edition
Item #: 21411
List: from $42.00
Member: from $37.80

The next edition of this standard is now open for Public Comment.

What is NFPA 214?
NFPA 214: Document Scope
1.1.1* This standard applies to fire protection for field-erected and factory-assembled water-cooling towers of combustible construction or those in which the fill is of combustible material. 1.1.2* Fire Risk Analysis. The following are some of the factors that shall be considered in determining the extent and method of fire protection required for induced-draft and natural-draft cooling towers: (1) Importance to continuity of operation (2)* Size and construction of tower (3) Type of tower (4) Location of tower (5) Water supply (6) Value of tower (7) Climate (8)* Water delivery time (9) Environment (10) Rooftop towers (11) Limited access (12) Construction of materials (See 1.1.3.) 1.1.3 Construction Materials of Cooling Towers. When the cooling towers' structure, fan and distribution decks, louvers, and fill materials are all of noncombustible materials, no fire protection is required. If any of these are combustible materials and the factors in 1.1.2 necessitate it, fire protection shall be provided in accordance with Chapter 3 and towers shall be located in accordance with Chapter 2. All other chapters shall be considered mandatory requirements.
This standard applies to fire protection for field-erected and factory-assembled water-cooling towers of combustible construction or those in which the fill is of combustible material. Official document scope
What does NFPA 214 address?
Provisions help you determine the type and amount of fire protection needed by taking into account factors such as importance to continuity of operation, size and construction of tower, type of tower, location of tower, water supply, and climate. Chapters cover location of water-cooling towers, fire protection, electrical equipment and wiring, internal combustion engine-driven fans, and maintenance. Table of Contents