NFPA 497: Recommended Practice for the Classification of Flammable Liquids, Gases, or Vapors and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas
Current Edition: 2012 Next Edition: 2017

Alerts: Receive e-mail updates on this document Manage my alerts

Alert Me
Please confirm you would like to be alerted the next time we post new information about document .
Alerts will be sent to the e-mail address on your user profile:

Thank you for signing up for alerts.

Committee members: Sign-in to view your documents.
What is NFPA 497?
NFPA 497: Document Scope
1.1 Scope. 1.1.1 This recommended practice applies to those locations where flammable gases or vapors, flammable liquids, or combustible liquids are processed or handled; and where their release into the atmosphere could result in their ignition by electrical systems or equipment. 1.1.2 This recommended practice provides information on specific flammable gases and vapors, flammable liquids, and combustible liquids whose relevant combustion properties have been sufficiently identified to allow their classification into the groups established by NFPA 70, National Electrical Code (NEC), for proper selection of electrical equipment in hazardous (classified) locations. The tables of selected combustible materials contained in this document are not intended to be all-inclusive. 1.1.3 This recommended practice applies to chemical process areas. As used in this document, a chemical process area could be a large, integrated chemical process plant or it could be a part of such a plant. It could be a part of a manufacturing facility where flammable gases or vapors, flammable liquids, or combustible liquids are produced or used in chemical reactions, or are handled or used in certain unit operations such as mixing, filtration, coating, spraying, and distillation. 1.1.4 This recommended practice does not apply to situations that could involve catastrophic failure of or catastrophic discharge from process vessels, pipelines, tanks, or systems. 1.1.5 This recommended practice does not address the unique hazards associated with explosives, pyrotechnics, blasting agents, pyrophoric materials, or oxygen-enriched atmospheres that might be present.
This recommended practice presents criteria to determine ignitability hazards in chemical process areas using flammable liquids, gases, or vapors to assist in the selection of electrical systems and equipment for safe use in Class I hazardous (classified) locations. Official document scope
What does NFPA 497 address?
Users will gain a basic understanding of the parameters that determine the degree and extent of the hazardous (classified) location. Information is provided on specific flammable gases and vapors, flammable liquids, and combustible liquids whose relevant combustion properties have been sufficiently identified to allow their classification into the groups established by NFPA 70, National Electrical Code. Table of Contents