Home
Codes & Standards
Code development process
Technical Committees
Special Information
| Important recommendations for the fire service and other PASS users In spite of the problems with PASS, NFPA believes that PASS remain an important tool for fire fighters and other emergency responders. NFPA recommends that, at least until PASS designed and certified to the new 2007 edition of NFPA 1982 become available, emergency responders continue to maintain and use existing PASS. Users are cautioned, however, that both the existing as well as the new PASS (when available) should always be considered a last resort call for help for emergency responder personnel who are unable to otherwise notify others that they are in distress. Fire fighters and other emergency responders should continue to activate and wear PASS whenever in hazardous areas of any incident, but should also be aware of the possibility that hostile conditions may adversely affect the operation of PASS. Incident command should continue to apply all personnel accountability measures at all incidents to assure the safe entrance and exit of personnel from hazardous areas.Direct supervision of operating companies or teams should provide for the safe operating locations of personnel and ensure that members do not "freelance" on the incident scene. |
PASS performance issues addressed in new edition of NFPA standard
The 2007 Edition of NFPA 1982, Standard on Personal Alert Safety Systems (PASS) is now available
In late 2005, NFPA published an alert notice entitled "PASS alarm signals can fail at high temperatures " on the NFPA Web site advising emergency responders, especially fire fighters, of high temperature exposures causing the loudness of PASS alarm signals to be reduced. This reduction in loudness can cause the alarm signal to become indistinguishable from background noise at the incident scene. This problem was brought to the attention of the NFPA Technical Committee on Electronic Safety Equipment by the National Institute for Occupational Safety and Health’s (NIOSH) Fire Fighter Fatality Investigation and Prevention Program.
NIOSH reported that during the investigation of four fire fighter fatalities that occurred from 2001 to 2004, the PASS alarm signals were not heard or were barely audible. The PASS had been certified as compliant to NFPA 1982, Standard on Personal Alert Safety Systems (PASS), 1998 Edition, and involved both stand-alone PASS and SCBA-integrated PASS.
Laboratory testing of PASS by the National Institute for Standards and Technology’s (NIST) Fire Research Division has shown that this sound reduction begins to occur at temperatures as low as 300° F (150° C) and affected all PASS evaluated by NIST that were certified to the 1998 edition and earlier editions of NFPA 1982.
The new, 2007 edition of NFPA 1982Continued reporting of PASS performance issues encouraged
The Technical Committee anticipates that further knowledge concerning PASS performance will be gained as PASS designed and certified to the 2007 edition of NFPA 1982 become available and are put into use in emergency conditions. The Technical Committee, in cooperation with NIOSH and NIST, will continue to monitor the performance of PASS in order to assure that any issues and developments can be addressed through further revisions to NFPA 1982 as appropriate. Emergency services organizations and emergency responder personnel can greatly assist in this monitoring activity by reporting any PASS malfunctions and other problems with proper functioning of PASS directly to both the certification organization whose certification mark appears on the PASS, and to NIOSH – NPPTL. Be sure to give your contact information so they can follow up with you.
NIOSH will forward any relevant information that it receives to NFPA for the consideration of the Technical Committee in maintaining and updating NPFA 1982.
See sidebar for Important recommendations for the fire service and other PASS users.
February 12, 2007: IAFC board issues position statement on PASS device investigation
NFPA's previous Alert Notice of December 2005
(for an important update, see NFPA Alert Notice Update of February 2007)
PASS alarm signals can fail at high temperatures
Exposure to high temperature environments may cause the loudness of PASS alarm signals to be reduced. This reduction in loudness could cause the alarm signal to become indistinguishable from background noise at the incident scene. This problem was brought to the attention of the NFPA Technical Committee on Electronic Safety Equipment by the National Institute for Occupational Safety and Health’s (NIOSH) Fire Fighter Fatality Investigation and Prevention Program.
NIOSH reported that during the investigation of four fire fighter fatalities that occurred from 2001 to 2004, the PASS alarms were not heard or were barely audible. The PASS had been certified as compliant to NFPA 1982, Standard on Personal Alert Safety Systems (PASS), 1998 Edition, and involved both stand-alone PASS and SCBA-integrated PASS.
Initial laboratory testing of PASS by the National Institute for Standards and Technology’s (NIST) Fire Research Division has shown this sound reduction may begin to occur at temperatures as low as 300° F (150° C) and could affect all PASS. Additional work is required to better characterize the thermal conditions (temperatures and exposure durations) that contribute to alarm signal degradation.
While the NFPA Technical Committee on Electronic Safety Equipment has been working to develop appropriate revisions to NFPA 1982 to address this issue, adequate solutions have not yet been presented. The Committee, in cooperation with NIOSH and NIST, will continue to study the issue and will incorporate revisions into NFPA 1982 as solutions are developed and consensus around addressing the issue is achieved.
PASS has always been a “last resort call for help” for emergency services personnel who are unable to otherwise notify others that they are in distress. Fire fighters should continue to activate and wear PASS whenever in hazardous areas of any incident, but should also be aware that high temperatures could cause degradation of the alarm signal. Incident command should continue to apply all personnel accountability measures at all incidents to assure the safe entrance and exit of personnel from hazardous areas. Direct supervision of operating companies or teams should provide for the safe operating locations of personnel and ensure that members do not “freelance” on the incident scene.
Emergency services organizations and emergency response personnel should report any PASS malfunctions and other problems with PASS functioning directly to both the certification organization whose certification mark appears on the PASS, and to NIOSH–NPPTL. Be sure to give your contact information so they can respond to you.