The Department of Homeland Security, The Office of State and Local Government Coordination and Preparedness, has requested that NFPA make available the following excerpt to assist fire departments with the application process of the SAFER Act Grant. The following material is excerpted from NFPA 1710 and does not reflect the full requirements of the standard.
Chapter 1 Administration
1.1 Scope.
1.1.1 This standard contains minimum requirements relating to the organization and deployment of fire suppression operations, emergency medical operations, and special operations to the public by substantially all career fire departments.
1.1.2 The requirements address functions and objectives of fire department emergency service delivery, response capabilities, and resources.
1.1.3 This standard also contains minimum requirements for managing resources and systems, such as health and safety, incident management, training, communications, and pre-incident planning.
1.1.4 This standard addresses the strategic and system issues involving the organization, operation, and deployment of a fire department and does not address tactical operations at a specific emergency incident.
1.2 Purpose.
1.2.1 The purpose of this standard is to specify the minimum criteria addressing the effectiveness and efficiency of the career public fire suppression operations, emergency medical service, and special operations delivery in protecting the citizens of the jurisdiction and the occupational safety and health of fire department employees.
Chapter 3 Definitions
3.2.2 Authority Having Jurisdiction (AHJ). An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation, or a procedure.
3.3.22 Initial Full Alarm Assignment. Those personnel, equipment, and resources ordinarily dispatched upon notification of a structural fire.
Chapter 5 Fire Department Services
5.2.4.1 Initial Arriving Company.
5.2.4.1.1 The fire department's fire suppression resources shall be deployed to provide for the arrival of an engine company within a 4-minute response time and/or the initial full alarm assignment within an 8-minute response time to 90 percent of the incidents as established in Chapter 4.
5.2.4.1.2* Personnel assigned to the initial arriving company shall have the capability to implement an initial rapid intervention crew (IRIC).
5.2.4.2 Initial Full Alarm Assignment Capability.
5.2.4.2.1 The fire department shall have the capability to deploy an initial full alarm assignment within an 8-minute response time to 90 percent of the incidents as established in Chapter 4.
5.2.4.2.2 The initial full alarm assignment shall provide for the following:
(1) Establishment of incident command outside of the hazard area for the overall coordination and direction of the initial full alarm assignment. A minimum of one individual shall be dedicated to this task.
(2) Establishment of an uninterrupted water supply of a minimum 1520 L/min (400 gpm) for 30 minutes. Supply line(s) shall be maintained by an operator who shall ensure uninterrupted water flow application.
(3) Establishment of an effective water flow application rate of 1140 L/min (300 gpm) from two hand-lines, each of which shall have a minimum of 380 L/min (100 gpm). Each attack and backup line shall be operated by a minimum of two individuals to effectively and safely maintain the line.
(4) Provision of one support person for each attack and backup line deployed to provide hydrant hookup and to assist in line lays, utility control, and forcible entry.
(5) A minimum of one victim search and rescue team shall be part of the initial full alarm assignment. Each search and rescue team shall consist of a minimum of two individuals.
(6) A minimum of one ventilation team shall be part of the initial full alarm assignment. Each ventilation team shall consist of a minimum of two individuals.
(7) If an aerial device is used in operations, one person shall function as an aerial operator who shall maintain primary control of the aerial device at all times.
(8) Establishment of an IRIC that shall consist of a minimum of two properly equipped and trained individuals.
Additional information
| NFPA 1710 |
|||||||||||
| NFPA 1720 |
|||||||||||