Code Compliant Electrical Installation the Key to Swimmer Safety and a Secure Electrical System in Pools

Now that summer has arrived, many of us will be taking advantage of the nice weather to jump into swimming pools to cool off. But what many people don’t realize, is there’s a lot to keeping us safe from electrical hazards in these wet environments. Much of this depends on the initial electrical installation. Something that is often overlooked after the pool has been installed and inspected, is maintenance of the pool and associated pool equipment. As we all know, Father Time is not always kind to electrical installations, which may require re-inspections for safety. Based on changes to the 2020 National Electrical Code® (NEC®) the authority having jurisdiction (AHJ) is permitted to periodically inspect and test pools. If they so choose, municipalities can now implement a process to periodically inspect and test pools, associated pool equipment, and the equipotential bonding after the initial installation inspection to help ensure reliability and continued safety.

Pool perimeter surfaceA code compliant electrical installation for a pool, completed by a licensed qualified electrician, is vital to the overall performance of the electrical system and the swimmer’s ability to cool off safely. The conductive pool shell, perimeter surfaces, metal forming shell for underwater luminaires, ladder cups, diving board bracket, the water, and other metal surfaces are where the equipotential bonding system is found. This equipotential bonding system surrounds the pool with connections to a #8 AWG solid copper conductor. This solid copper conductor is terminated to all the above points then routed underground or within the concrete, back to the pool pump motor and terminated on the grounding lug located on pump motor. The NEC in Section 680.26(B)(6) requires sufficient length in the equipotential bonding conductor for future pump replacement. Best practice would be to provide enough additional conductor to terminate it anywhere on the motor in the event the lug is not in the same location. These connections are crucial to equalizing the electrical potential of all conductive surfaces, ladders, diving boards, underwater luminaries, and water that are all found with pools. Because pools are subject to corrosion and use corrosive chemicals, terminations, many of which are underground or within concrete, must be listed and labeled for the environment they are being installed in.

People often think that once a pool is installed, all they need to do is add chemicals to the water and clean the pool. This myth is where problems arise as maintenance and periodic inspection and testing of the pool equipment is a very important part of the overall electrical safety of the pool. Ground Fault Circuit Interrupters (GFCIs) need to be tested in accordance with the manufacturer’s installation instructions, which is typically monthly. Also, as a part of the maintenance, grounding connections should be checked for corrosion, loose connections, or rust; all of these can inhibit the functioning of the equipotential bond, which could result in an electrical shock or an electric shock drowning (ESD). If corrosion is seen on any terminations, those points should be cleaned and or replaced by a qualified person as these connections are crucial to the safety of the people who use the pool.

Pool pump motors do not last forever and therefore must be replaced, which requires the disconnection and reconnection of the equipotential bonding conductor from the motor. As previously mentioned, additional slack in the solid copper conductor is required at the motor location for motor replacement because consideration was taken for bonding lug location. When a state chooses to legislatively adopt the 2020 NEC, which makes it enforceable by an AHJ, Section 680.4 permits the periodic inspection and testing by the AHJ of the pool system. This may help encourage the maintenance and repair of the pool system and equipotential bond.  

Maintenance on pools, associated pool equipment, and the equipotential bonding system is no different than maintaining a car by getting the oil changed. It is not difficult to do; the 2020 NEC provides this direction and is instrumental in helping to prevent a fun day at the pool from turning into a tragedy. Find additional information and resources for electrical inspection professionals at nfpa.org/electricalinspection.

NFPA 70 the National Electrical Code® (NEC®) is now available in NFPA LiNK™, the association’s information delivery platform with NFPA codes and standards, supplementary content, and visual aids for building, electrical, and life safety professionals and practitioners. Learn more at nfpa.org/LiNK.   

Find more NFPA resources and information related to electrical inspections.